top, SATTEL (THAILAND) CO., LTD.

INDUCOM RE-2X(St)Yv-fl


หมวดสินค้า: TKD, Germany

หมวดย่อยสินค้า: สาย Instrumentation cables: เป็นสาย High speed, Low capacitance, XLPE insulation, Capacity: max. 115 nF/km



instrumentation cable, ทนน้ำมัน,ทนความร้อน,ทนความเย็น,ราคาถูก

Application

Instrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use and laying underground. When laying in the ground the local building regulations have to be observed.

Special Feature

  • more steady at higher frequencies and temperatures (+90°C) by XLPE core insulation (cross-linked PE)
  • high crosstalk and low cable attenuation
  • largely resistant to acids, bases and usual oils
  • Oil resitance: ICEA S-73-532 / NEMA WC 57-2004 § 6.9.3
  • robust version with strengthened outer sheath
  • suitable for intrinsically safe systems in zone 1+2 group II acc. IEC 60079-14
  • Sunlight resitance: UL 1581 Section 1200
  • flame-retardant acc. to IEC 60332-1-2 and IEC 60332-3-24 (Cat. C)

Remarks

  • conform to RoHS; conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
  • also available without strengthened outer sheath as RE-2X(St)Y-fl
  • we are pleased to produce special versions e.g. fire-resistant (Mica), halogen-free, oiland chemical-resistant (lead sheath or GuardSheath - unleaded), BS 5308, MESC etc. >> also available as compensation cable > INDUTHERM <<

Structure and Specifications

  • conductor material : bare copper strand
  • conductor class : 7-wired construction acc. to IEC 60228 cl. 2
  • core insulation : XLPE (cross-linked polyethylene)
  • core identification : pairs single-coloured with numerals; core A: bk, core B: wh; triple: core A: wh, core B: rd, core C: bk, core A and C with numerals
  • stranding : pairs stranded in layers
  • shield : plastic clad aluminium foil (24 μm) with subjacent tinned drain wire 0.5mm² (7x0.30 mm)
  • outer sheath : PVC
  • sheath colour : black or blue RAL 5015 for intrinsically safe systems
  • rated voltage : 300 V
  • testing voltage : 1,5 kV
  • conductor resistance : 0.5mm²: max.36.7 Ω/km; 0.75mm²: max.25.0 Ω/km; 1.0 mm²: max.18,5 Ω/km; 1.3mm²: max.14.2 Ω/km
  • insulation resistance : min. 5 GΩ x km
  • current carrying capacity : acc. to DIN VDE, s. Techn. Guidelines
  • capacity : max. 115 nF/km
  • inductivity : ca. 1 mH/km
  • coupling : max. 500 pF/500 m
  • other characteristics : L/R Ratio: 0.5mm²: max.25 μH/Ω; 0.75mm²: max.25 μH/ Ω; 1.0mm²: max.25 μH/Ω; 1.3mm²: max.40 μH/Ω
  • min. bending radius fixed : 7.5 x d
  • operat. temp. fixed min/max : -40°C / +70°C
  • operat. temp. moved min/max : -5°C / +50°C
  • burning behavior : self-extinguishing and flame-retardant acc. to IEC 60332-1-2 and IEC 60332-3-24 (Cat. C)
  • resistant to oil : ICEA S-73-532 / NEMA WC 57-2004 § 6.9.3
  • standard : EN 50288-7


Download Brochure (PDF)

 















Home | Company Profile | Certificate | Contact Us
PRIVACY POLICY: SATTELTHAILAND.COM COPYRIGHT © 2011 ALL RIGHTS RESERVED BY SATTELTHAILAND.COM | WEB DESIGN BY WEBCREATIONTEAM.COM